+91 98170 00052 info@syzeenvirosolution.com Monday to Saturday, 9 am to 6 pm
SYZE Enviro SolutionsTrusted Partner for Smart Environmental Monitoring Solutions

Electromagnetic flow meters

Full-pipe flow for STP inlets, ETP discharge and process lines, supplied and connected by SYZE

Electromagnetic flow meters use Faraday's law to measure velocity in conductive liquids. They are the standard for STP inlet and outlet metering, ETP discharge and industrial pipelines where full-pipe flow and high reliability are needed.

SYZE supplies the meter, sized to the pipe, and integrates it end to end with our own data logger, CPCB / PHED dashboards, telemetry and solar-ready RTUs, with reverse-flow alerts, local data backup and remote firmware updates.

How the meter measures

Electromagnetic flow meter A flanged electromagnetic flow sensor in a full pipe, with its transmitter on top sending readings over RS485 Modbus to the data logger. Inside the sensor, coils create a magnetic field B across the pipe; liquid flowing at velocity v induces a voltage U between two electrodes, proportional to the velocity: U = k × B × v × D. Flow RS485 Modbus Data logger Transmitter Sensor, flanged into the line Fitted where the pipe always runs full: in a low section or a rising line, never at a high point. Inside the sensor B v U electrode U = k × B × v × D
Faraday's law: liquid moving through the sensor's magnetic field induces a voltage proportional to its velocity.

System architecture

Sensor
Inline electromagnetic flow sensor, DN80–DN300
Converter
Transmitter with RS-485 Modbus output
RTU
SYZE RTU with solar charge controller, local memory and GSM/4G modem
Telemetry
Modbus to MQTT / HTTP / FTP uplink to the dashboard
Dashboard
Compliance view, event logs, PDF reports and API access

Capabilities

Electromagnetic sensing
Accurate full-pipe measurement with no moving parts.
Telemetry
Modbus RTU, MQTT, FTP and HTTP for cloud and regulatory systems.
Solar and battery operation
For sites without dependable power.
Event detection
Alerts for zero flow, tamper, dry run and reverse flow, with logs.
Sensor interfacing
Reads the common makes of electromagnetic flow meter over RS-485 Modbus.
Analytics
Compliance tagging, patterns and export-ready reports.
Reverse-flow detection
Reliable metering under back-pressure.
Pipeline monitoring
Water supply, ETP inlet / outlet and effluent pipelines.
STP inlet digitisation
Automatic inlet flow monitoring, integrated with existing SCADA.

See it working

Send us the pipe sizes and flow range and we will propose the meter and RTU.

Get a quote