+91 98170 00052 info@syzeenvirosolution.com Monday to Saturday, 9 am to 6 pm
SYZE Enviro SolutionsTrusted Partner for Smart Environmental Monitoring Solutions

Trusted Partner for Smart Environmental Monitoring Solutions

SYZE Enviro SolutionsOnline COD, BOD, TSS
and pH analysers.
Eight parameters as standard.

The SYZE-OCEMS-8P measures COD, BOD, TSS, pH, TOC, turbidity, temperature and flow at the outlet of a sewage treatment plant or ETP - all eight as standard - and our own data logger sends every reading to CPCB, HSPCB and PPCB. Installed and maintained by our own field team, with engineering experience in the family going back to 1988.

See the SYZE-OCEMS-8P Request a demonstration

Or try the demos online

  • Registered vendor with HSPCB and PPCB
  • Our own OEM data logger
  • CPCB, HSPCB and PPCB portals
  • Designed, installed and maintained by one team
SYZE-OCEMS-8P at an outfall End view of the outlet channel with a multi-parameter UV-Vis probe and a pH electrode hung from a bracket into the effluent, and an electromagnetic flow meter on the outfall line in its chamber. Each instrument is cabled to its own RS485 port on the data logger panel: port 1 the probe, port 2 the pH electrode, port 3 the flow meter, port 4 spare. The panel shows the readings on site and uploads them. outlet channel cable duct 1234 Data logger panel with local display uploads every reading 1 2 3 1 2 3 4 Multi-parameter UV–Vis probe pH electrode Electromagnetic flow meter Spare port COD, BOD, TSS, TOC, turbidity, temperature pH, temperature compensated Flow on the outfall line A second analyser later, no new hardware
The SYZE-OCEMS-8P at an outfall: the optical probe and pH electrode in the outlet channel, the flow meter on the outfall line, each read by the data logger and sent to every portal.
  • 1988Family engineering experience since
  • 2023SYZE Enviro Solutions founded
  • 52Projects for public agencies and industry
  • 8Parameters as standard in every analyser

Trusted by public agencies and industry

  • PHED Haryana
  • Gurugram Metropolitan Development Authority
  • Bharat Electronics
  • India Meteorological Department
  • VSNL
  • Tata Telecom
  • ICOMM
  • ARM Ltd.
  • Reliance Communications
  • Reliance Engineering Associates
  • HFCL
  • Nepal Doorsanchar Nigam

Proven across Haryana's public water infrastructure

  • 590MLD of STP capacity we have worked on
  • 30Sewage treatment plants we have worked on
  • 13PHED divisions and authorities served
  • 21Sites sending live data now

How it works

From the outfall to the board

  1. 1

    Instruments

    Analyser, pH electrode and flow meter, each on its own RS485 port.

  2. 2

    Data logger

    Reads over Modbus RTU, flags each reading and stores it on the unit first.

  3. 3

    Upload

    4G, Ethernet or Wi-Fi to CPCB, the State Board and the SYZE platform, each in its own format.

  4. 4

    Evidence

    Every submission kept with the data sent and the reply received.

If the internet link fails, readings keep being taken and stored. They upload in order when the link returns, so an outage costs no data.

Projects

Current and recent work

All projects
Water and effluentOngoing

Bahadurgarh STP, Line Par

Online monitoring device: supply, installation, testing and commissioning

Bahadurgarh, Jhajjar, Haryana

18.00 MLDPHED Bahadurgarh
Water and effluentOngoing

Rewari Town STP Unit I

Online monitoring of BOD, COD, TSS and pH — 16.00 MLD capacity

Rewari, Haryana

16.00 MLDPHED Rewari
Water and effluentOngoing

Rewari Town STP Unit II

Online monitoring of BOD, COD, TSS and pH — 8.00 MLD capacity

Rewari, Haryana

8.00 MLDPHED Rewari
Water and effluentOngoing

8 MLD STP, Pehowa, Kurukshetra

Online COD, BOD, pH and TSS analyser, flow meter, data to CPCB, HSPCB and PHED

Pehowa, Kurukshetra, Haryana

8.00 MLDPHED Haryana
Water and effluentOngoing

Rewari Town STP Unit III

Online monitoring of BOD, COD, TSS and pH — 6.50 MLD capacity

Rewari, Haryana

6.50 MLDPHED Rewari
Water and effluentOngoing

6 MLD STP, Model Town, Ambala City

STP automation: PLC SCADA, flow meters, data loggers, cloud dashboard, calibration and data transmission to CPCB and HSPCB

Model Town, Ambala City, Haryana

6.00 MLDPHED Haryana

Our legacy

Engineering for public infrastructure since 1988

Radomes for BEL, earth stations for VSNL, microwave towers across Jammu & Kashmir, pump houses and pipelines for PHED Haryana, flumes for GMDA: the work of Mr. Ashok Kumar Mehta since 1988. SYZE Enviro Solutions, founded in 2023, carries it into the monitoring that proves a plant is compliant.

Our history
  1. 1988Engineering works begin
  2. 1994–2003Telecom networks
  3. 2008Public water works
  4. 2019Flow monitoring at STPs
  5. 2022GMDA Gurugram
  6. 2023SYZE Enviro Solutions
  7. 2025–26OCEMS with long-term O&M

Talk to an engineer

Tell us about your plant, pipeline or site, and an engineer will get back to you.

Get a quote